ARTon Titanium Plus
On Line Uninterrupaible Power Supply
- First Class Double Conversion Uninterruptable Power Supply
- DSP Controlled High Reliability
- Output Power Factor: 0.8
- Graphic LCD Display and User Friendly Control Keys
- Green Energy with Input Power Factor (PFC) > 0.99
- 95% Efficiency with ECO Mode, 50/60 - 60/50 Running with Converter Mode
- Emergency Power Off Function (EPO), Operating Temperature 0 ~ 45C
- Ultra Wide Input Voltage Tolerance (110 ~ 300 VAC)
- Short Recharge Time (5 hours) & Long Backup Options
- Freee of Charge, Network Supported Monitoring & Control Software
- SNMP & AS400 Network Monitoring Options
- Silent & Economic Operation with Adjusted Fan Speed
- Automatic Restart & Control Start Operation
Capacity (VA/Watt) - 2000 VA / 1600 Watt
Input-Rectifier
Voltage-Voltage Tolerance - 220 VAC, 1 Phase + Neutral, 110 ~ 300 VAC
Voltage Tolerance According to Load %
Transfer to battery at 110 VAC for 0~60% load, 120 VAC for 61~70% load, 140 VAC for 71~80% load, 160 VAC for 81~100% load (Tolerance+/- 5V)
Transfer to battery at 300 VAC for 0~100% load, transfer back to the mains at 285 VAC for 0~100% load
Power Factor - >=0.99
Current (maximum) - 9.6A
Frequency - 46~54 Hz
Output - Inverter & Bypass
Power Factor - 0.8
Voltage - Voltage Tolerance - 220 VAC +/-2%
Dynamic Response - Maximum Deviation <= 6% AT 20-100% lOAD cHANGE, <=9% AT 0-100% lOAD cHANGE
Correction Time - 100 mili seconds to be with in +/- 2% Static Tolerance at 0-100-0% Load Change
Frequency - Frequency Tolerance - 50 Hz, +/- 0.2 Hz for Battery Operation
Voltage Waveform - Pure Sine Wave
Total Harmonic Distortion - <=3% at linear load
Crest Factor - 3:1
Overload Capacity - 30 seconds for 110-150%, 300 mili seconds for > 150% Over Load
Short Circuit Protection - Electronic Short Circuit Protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery Mode, 2.5 mili seconds for Inverter to Bypass Mode
Bypass Tolerance & Adjustment - 80 ~ 286 VAC Adjustable, Bypass can be Disabled or Enabled to Use in Standby Mode
Battery
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12V 7Ah x 8 pieces
Backup Time (100% SMPS Load) - 13 minutes
Float Charge Voltage - 110 +/- 0.4 VDC
End of Discharge Voltage - 80 VDC
Battery Charge Currenty & Charge Time - Standard 1 Amper Charge Current, 5 hours Charge Time to 90% Capacity After Discharge, Optional High Capacity Charger for Long Backup Demand
Indications & Control panel
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warning - UPS Status, Input/Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustments ECO Mode, Converter Mode
Protections
Over Load - 60sn at 105%~110% Load, 30sn at 111%-125% Load, 10sn at 126%~150% Load, 1sn at 150% Load Transfer to Bypass Without Any Break After Over Load Period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load Transfer to Bypass for 90C Internal Temperature, Transfer Back to Inverter When Internal Temperature < 80C
Modem / Network Protection - Surge Protection for Modem / Network Line
Audible Warnings
Warning Type and Warnings
Buzzer, Mutable with Audible Alarm Disable
Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Over Load
Communications
Interface & Protocol - Smart RS232 Communication with DB9 Port, Optional SNMP or AS400 Support
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
General
Efficiency - AC to AC at 100% / at ECO Mode - 88 % / 95 %
Noise Level - < 50 dBA
Electro Magnetic Compatibility - EN 62040-1, EN 62040-2, 62040-3, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
Operating Temperature & Humidity - 0~45C, Maximum 20~90 % (Non Condensed)
Storage Temperature -20C~70C
Protection Class - IP 20
Cooling Type - Force Cooling Fan with Adjusted Speed
Operating Altitude - < 1000 meters (from Sea Level)
Dimensions (mm), W x H x D - 192 x 340 x 460
Weight, without / with Battery (kg) - 15 / 34.5
Виж още UPS Artronic
Виж всички UPS в категорията
On Line Uninterrupaible Power Supply
- First Class Double Conversion Uninterruptable Power Supply
- DSP Controlled High Reliability
- Output Power Factor: 0.8
- Graphic LCD Display and User Friendly Control Keys
- Green Energy with Input Power Factor (PFC) > 0.99
- 95% Efficiency with ECO Mode, 50/60 - 60/50 Running with Converter Mode
- Emergency Power Off Function (EPO), Operating Temperature 0 ~ 45C
- Ultra Wide Input Voltage Tolerance (110 ~ 300 VAC)
- Short Recharge Time (5 hours) & Long Backup Options
- Freee of Charge, Network Supported Monitoring & Control Software
- SNMP & AS400 Network Monitoring Options
- Silent & Economic Operation with Adjusted Fan Speed
- Automatic Restart & Control Start Operation
Capacity (VA/Watt) - 2000 VA / 1600 Watt
Input-Rectifier
Voltage-Voltage Tolerance - 220 VAC, 1 Phase + Neutral, 110 ~ 300 VAC
Voltage Tolerance According to Load %
Transfer to battery at 110 VAC for 0~60% load, 120 VAC for 61~70% load, 140 VAC for 71~80% load, 160 VAC for 81~100% load (Tolerance+/- 5V)
Transfer to battery at 300 VAC for 0~100% load, transfer back to the mains at 285 VAC for 0~100% load
Power Factor - >=0.99
Current (maximum) - 9.6A
Frequency - 46~54 Hz
Output - Inverter & Bypass
Power Factor - 0.8
Voltage - Voltage Tolerance - 220 VAC +/-2%
Dynamic Response - Maximum Deviation <= 6% AT 20-100% lOAD cHANGE, <=9% AT 0-100% lOAD cHANGE
Correction Time - 100 mili seconds to be with in +/- 2% Static Tolerance at 0-100-0% Load Change
Frequency - Frequency Tolerance - 50 Hz, +/- 0.2 Hz for Battery Operation
Voltage Waveform - Pure Sine Wave
Total Harmonic Distortion - <=3% at linear load
Crest Factor - 3:1
Overload Capacity - 30 seconds for 110-150%, 300 mili seconds for > 150% Over Load
Short Circuit Protection - Electronic Short Circuit Protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery Mode, 2.5 mili seconds for Inverter to Bypass Mode
Bypass Tolerance & Adjustment - 80 ~ 286 VAC Adjustable, Bypass can be Disabled or Enabled to Use in Standby Mode
Battery
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12V 7Ah x 8 pieces
Backup Time (100% SMPS Load) - 13 minutes
Float Charge Voltage - 110 +/- 0.4 VDC
End of Discharge Voltage - 80 VDC
Battery Charge Currenty & Charge Time - Standard 1 Amper Charge Current, 5 hours Charge Time to 90% Capacity After Discharge, Optional High Capacity Charger for Long Backup Demand
Indications & Control panel
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warning - UPS Status, Input/Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustments ECO Mode, Converter Mode
Protections
Over Load - 60sn at 105%~110% Load, 30sn at 111%-125% Load, 10sn at 126%~150% Load, 1sn at 150% Load Transfer to Bypass Without Any Break After Over Load Period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load Transfer to Bypass for 90C Internal Temperature, Transfer Back to Inverter When Internal Temperature < 80C
Modem / Network Protection - Surge Protection for Modem / Network Line
Audible Warnings
Warning Type and Warnings
Buzzer, Mutable with Audible Alarm Disable
Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Over Load
Communications
Interface & Protocol - Smart RS232 Communication with DB9 Port, Optional SNMP or AS400 Support
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
General
Efficiency - AC to AC at 100% / at ECO Mode - 88 % / 95 %
Noise Level - < 50 dBA
Electro Magnetic Compatibility - EN 62040-1, EN 62040-2, 62040-3, EN 60950-1, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5
Operating Temperature & Humidity - 0~45C, Maximum 20~90 % (Non Condensed)
Storage Temperature -20C~70C
Protection Class - IP 20
Cooling Type - Force Cooling Fan with Adjusted Speed
Operating Altitude - < 1000 meters (from Sea Level)
Dimensions (mm), W x H x D - 192 x 340 x 460
Weight, without / with Battery (kg) - 15 / 34.5
Виж още UPS Artronic
Виж всички UPS в категорията
Технически характеристики
Изходяща мощност: | 2000 VA |
---|---|
Тип: | ON Line |
Формфактор: | Tower |
Добави Ревю / Въпрос
Оцени продукта или задай въпрос?
- 5
- 4
- 3
- 2
- 1
Свързани продукти
-
UPS PowerWalker DC SecureAdapter 10120431, 12VA/12W, малък UPS за устройства на 12V(рутери/декодери/IP камери), 2600 mAh Li-Ion батерия, до 3 часа поддръжка
57.53лв
-
UPS Njoy Keen 600 UPLI-LI060KE-CG01B, 600VA/360W, Line Interactive, Tower
98.57лв
-
UPS Njoy Keen 600 UPLI-LI060KU-CG01B, 600VA/360W, Line Interactive, Tower
100.92лв