ARTon Titanium Series 3.1 10 - 15 - 20 kVA
• VFI Topology Class 1 Double Conversion UPS
• Graphic LCD Display and Touchpad Control Keys
• Green Energy with Input Power Factor Correction (PFC)
• Automatic Restart & Cold Start Function
• Network Supported Monitoring & Control Software
• SNMP & AS400 Network Monitoring Options
• Silent & Economic Operation with Adjusted Fan Speed
• Integrated Maintenance Bypass Switch
• 3 Units in Paralel / Redundant Operation
ARTon Titanium 3.1-20 kVA
Capacity (VA / Watt) - 20000 VA / 14000 W
3 In Parallel Capacity (VA / Watt) - 60000 VA / 42000W
INPUT - RECTIFIER
Voltage & Voltage Range - 380 VAC, 3 Phase + Neutral
Voltage Tolerance - 304 ? 478 VAC ± 3%
Power Factor - > 0.95
Current (nominal) - 30.3 A / Phase - 91 A
Frequency & Frequency Range - 50 Hz, 46 ~ 54 Hz, Adjustable to work with Any Generator
OUTPUT - INVERTER and BYPASS
Load Power Factor Range - 0.65 ~ 1.0
Voltage & Voltage Tolerance - 220 / 230 / 240 VAC ± 1%
Dynamic Response - Maximum Deviation ? 5% at 50% - 100 - 50% Load Change
Recovery Time - 60 mili seconds to be with in ± 1% Static Tolerance at 0-100-0 % Load Change
Total Harmonic Distortion (THD) - ? 2% at linear load, ? 6% at non linear load
Frequency & Frequency Range - 50 Hz, ± 0.05 Hz Battery Operation
Voltage Waveform - Pure Sine Wave
Crest Factor - 3 : 1
Over Load - 10 minutes for 105 ~130%, > 130% Transfer to Bypass after 1 second, Shutdown after 1 minute (in Line Mode)
Short Circuit Protection - Electronic short circuit protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery and Inverter to Bypass Mode
Bypass Tolerance & Adjustment - 176 ? 261 VAC Adjustable, Bypass can be Disable or Enable to use in Standby Mode
BATTERY
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12 V 9 Ah x 40 pieces
Backup Time (100% / 50% Load) - 6 / 15 minutes
Nominal / Charge Voltage - 240 / 274 VDC ± 1%
End of Discharge Voltage - 220 VDC ± 3 VDC
Battery Charge Current & Charging Time - Standard 2 A Charge Current for 6-10 kVA, 7-8 hours Charge Time to 90% Capacity after Discharge, 4.2 A Charge Current for 3.1 10-15-20 kVA
INDICATORS & CONTROL PANEL
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warnings - UPSStatus, Input / Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustment
PROTECTIONS
Overload - Electronic Protection, Load Transfer to Bypass without any break after Overload period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load transfer to Bypass for 90°C Internal Temperature, Transfer back to Inverter when Internal Temperature < 80°C
Modem / Network Protection - Surge protection for Modem / Network line
AUDIBLE ALARMS
Warning Type and Warnings - Buzzer, Mutable with Audible Alarm Disable; Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Overload
COMMUNICATIONS
Interface & Protocol - Smart RS232 Communication with DB9 (female) Port, Optional SNMP & AS400
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
GENERAL
Efficiency - AC to AC At 100% - 88%
Noise Level - ? 60 dBA
Electro Magnetic Compatibility - EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI)
Operation Temperature & Humidity - 0 °C ~ 40 °C, maximum 20~90% (Non Condensed)
Storage Temperature - -20 °C ~ +70 °C
Protection Class - IP20
Cooling Type - Forced cooling Fan with Adjusted Speed
Operation Altitude - < 1000 meters (from the sea level)
Dimensions (mm), W x H x D - 260 x 717 x 570
Weight, without / with Battery (kg) - 55 / 177
Software:
Winpower Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
*Гаранция на устройството - 2 г.
Виж още UPS Artronic
Виж всички UPS в категорията
• VFI Topology Class 1 Double Conversion UPS
• Graphic LCD Display and Touchpad Control Keys
• Green Energy with Input Power Factor Correction (PFC)
• Automatic Restart & Cold Start Function
• Network Supported Monitoring & Control Software
• SNMP & AS400 Network Monitoring Options
• Silent & Economic Operation with Adjusted Fan Speed
• Integrated Maintenance Bypass Switch
• 3 Units in Paralel / Redundant Operation
ARTon Titanium 3.1-20 kVA
Capacity (VA / Watt) - 20000 VA / 14000 W
3 In Parallel Capacity (VA / Watt) - 60000 VA / 42000W
INPUT - RECTIFIER
Voltage & Voltage Range - 380 VAC, 3 Phase + Neutral
Voltage Tolerance - 304 ? 478 VAC ± 3%
Power Factor - > 0.95
Current (nominal) - 30.3 A / Phase - 91 A
Frequency & Frequency Range - 50 Hz, 46 ~ 54 Hz, Adjustable to work with Any Generator
OUTPUT - INVERTER and BYPASS
Load Power Factor Range - 0.65 ~ 1.0
Voltage & Voltage Tolerance - 220 / 230 / 240 VAC ± 1%
Dynamic Response - Maximum Deviation ? 5% at 50% - 100 - 50% Load Change
Recovery Time - 60 mili seconds to be with in ± 1% Static Tolerance at 0-100-0 % Load Change
Total Harmonic Distortion (THD) - ? 2% at linear load, ? 6% at non linear load
Frequency & Frequency Range - 50 Hz, ± 0.05 Hz Battery Operation
Voltage Waveform - Pure Sine Wave
Crest Factor - 3 : 1
Over Load - 10 minutes for 105 ~130%, > 130% Transfer to Bypass after 1 second, Shutdown after 1 minute (in Line Mode)
Short Circuit Protection - Electronic short circuit protection
Bypass & Transfer Time - Standard Static Bypass, 0 (zero) for Line Mode to Battery and Inverter to Bypass Mode
Bypass Tolerance & Adjustment - 176 ? 261 VAC Adjustable, Bypass can be Disable or Enable to use in Standby Mode
BATTERY
Type & Placement - Maintenance Free Dry Type Battery, Internal or External Regarding to Demand
Capacity & Quantity - 12 V 9 Ah x 40 pieces
Backup Time (100% / 50% Load) - 6 / 15 minutes
Nominal / Charge Voltage - 240 / 274 VDC ± 1%
End of Discharge Voltage - 220 VDC ± 3 VDC
Battery Charge Current & Charging Time - Standard 2 A Charge Current for 6-10 kVA, 7-8 hours Charge Time to 90% Capacity after Discharge, 4.2 A Charge Current for 3.1 10-15-20 kVA
INDICATORS & CONTROL PANEL
Type - Graphic LCD Panel
Control Panel - Touchpad Buttons (On/off, Audible Alarm Disable, Up/Down, Enter)
Measurements & Warnings - UPSStatus, Input / Output Voltage & Frequency, Load %, Battery Capacity & Voltage, Warning & Alarm Messages
Indications (LCD) - Mimic Diagram for Energy Flow, Measurements, Warnings, Faults, Adjustment
PROTECTIONS
Overload - Electronic Protection, Load Transfer to Bypass without any break after Overload period
Short Circuit - Automatic Inverter Shutdown
Over Temperature - Load transfer to Bypass for 90°C Internal Temperature, Transfer back to Inverter when Internal Temperature < 80°C
Modem / Network Protection - Surge protection for Modem / Network line
AUDIBLE ALARMS
Warning Type and Warnings - Buzzer, Mutable with Audible Alarm Disable; Different Audible Signals for Battery Operation, Battery Low Voltage, UPS Fault, Overload
COMMUNICATIONS
Interface & Protocol - Smart RS232 Communication with DB9 (female) Port, Optional SNMP & AS400
Software - Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
GENERAL
Efficiency - AC to AC At 100% - 88%
Noise Level - ? 60 dBA
Electro Magnetic Compatibility - EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI)
Operation Temperature & Humidity - 0 °C ~ 40 °C, maximum 20~90% (Non Condensed)
Storage Temperature - -20 °C ~ +70 °C
Protection Class - IP20
Cooling Type - Forced cooling Fan with Adjusted Speed
Operation Altitude - < 1000 meters (from the sea level)
Dimensions (mm), W x H x D - 260 x 717 x 570
Weight, without / with Battery (kg) - 55 / 177
Software:
Winpower Free of Charge, Network Supported Monitoring & Control Software, Software Supports Windows 98/ME/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix 4.3 & 5.1x, HP-UX 11.x, Compaq True 64, SGI Irix, Free BSD, Unix Systems, MAC Supported
*Гаранция на устройството - 2 г.
Виж още UPS Artronic
Виж всички UPS в категорията
Технически характеристики
Изходяща мощност: | 20000 VA |
---|---|
Формфактор: | Tower |
Добави Ревю / Въпрос
Оцени продукта или задай въпрос?
- 5
- 4
- 3
- 2
- 1
Свързани продукти
UPS PowerWalker DC SecureAdapter 10120431, 12VA/12W, малък UPS за устройства на 12V(рутери/декодери/IP камери), 2600 mAh Li-Ion батерия, до 3 часа поддръжка
61.14лв
UPS Hikvision DS-UPS600, 600VA/360W, Online, LCD дисплей, Tower
81.98лв
UPS Njoy Keen 600 UPLI-LI060KE-CG01B, 600VA/360W, Line Interactive, Tower
98.57лв