RT Series 10 kVA; ART Series
* High Reliability with the Digital Signal Processor (DSP) Control
* Power Extension and Redundancy with Parallel / Redundant Operation
* Parallel / Redundant connection up to 3 pcs
* High Reliability and Low Operation Cost
* Energy Efficiency with Input Power Factor Correction (PFC) Power Factor: 0,95-0,98
* Cooling System with Variable Speed Fans
* Automatic Restart and Cold Start Function
* Manual Bypass Switch
Technical Specifications
MODEL ART 1.1-10 kVA
Power(VA/Watt) 10000VA/7000W
Power(VA/Watt) - Paralelling With 3 pcs Parallel Connection, Total 30000 VA / 21000W
Voltage & Voltage Range 220 VAC, 1 Phase + Neutral
Voltage Tolerance 176 ? 276 VAC ± 3%
Power Factor ? 0.98
Current (nominal) 37 Ampere
Input Fuse 50 A NFB
Frequency & Frequency Range 50 Hz, 46 ~ 54 Hz
Working with Gen Set Perfect Voltage and frequency Compatibility
OUTPUT - INVERTER and BYPASS
Load Power Factor Range 0.65 inductive - 1.0 resistive
Voltage Wave Form Sinusoidal
Voltage & Voltage Tolerance 220 / 230 / 240 VAC ± 1%
Dynamic Response At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5%
Recovery Time
At Dynamic load Changes, Output Voltage recovery time is 60 msec ± 1%
Total Harmonic Distortion For Linear Load ? 2%, Non Linear Load ? 6%
Frequency & Frequency Range 50 Hz / Mains 46-54 Hz, Battery Mode ± 0.1% (0.05 Hz)
Crest Factor 3 : 1
Over Load (Mains) For 105% - 130% load 10 mins., for > 130% load transfer to bypass after 1 sec, shutdown after 1 min at overloaded bypass
Over Load (Battery) At > 105% load shut down after 10 sec.
Short Circuit Protection Electronic short circuit protection, short circuit current 130% x Inom
Bypass and Transfer Time Standard static bypass, Completely Uninterrupted transfer between Mains - Battery / Battery - Mains
Bypass Voltage Tolerance 176 ? 261 VAC, 1 Phase + Neutral
BATTERY
Type and Placement Maintenance Free, Dry Type, Internal Maintenance Free, Dry Type, With External Battery Cabinet
Capacity and Number 12 V 9 Ah x 20 pcs
Battery Time (100% / 50% Load) 6 mins / 15 mins
Nominal Battery Voltage 240 VDC
Battery Low Voltage 220 VDC ± 3
Battery Charging Current and Charging Time
2 Ampere, 8 hours to 90% after complete discharge
INDICATORS & CONTROL PANEL
Type LED Panel
Control Panel Push Buttons (Open / Close, Audible Alarm Cancellation)
Measuring and Alarms % Load, Input Voltage Exist, Output Voltage Exist, Bypass Active, Battery Mode, Battery Capacity (%), Inverter in Service, Fault
Indicators (LED) Mains On, Mains Reverse, Battery Mode, Bypass On, Load / Battery Level, Overload, Fault
PROTECTIONS
Overload
Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption
Short Circuit
Inverter shuts down automatically
Over Temperature
If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work
Modem / Network Protection
Modem / Network protection input against to Voltage Spikes
AUDIBLE ALARMS
Alarm Type and Alarms
Buzzer, it can be switched off by audible alarm button.
Battery Mode, Battery Low, UPS fault, Overload, Short Circuit, Over Charge, Charger, Bypass, Inverter fault, Communication fault
COMMUNICATION
Interface and Protocol
Standart DB 9 (Female) Port, Intelligent RS232 (standard), SNMP and AS400 Relay PCB (optional) DB25 parallel port (for paralelling)
Software
Free download from internet; communication and control from the network, Windows 95 / 98 / NT / 2000 / XP / 2003, Linux, Sun Solaris 7 / 8 / 9, IBM Aix4.3 ve 5.1x, HP-UX 11.x, FreeBSD, Unix Systems, MAC Compatible Software Support
GENERAL
Total Efficiency At 100% load 88%
Noise Level ? 55 dBA
Electro Magnetic Compatibility
EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI)
Operation Temperature and Humidity
0 °C ~ 40 °C, maximum 20-90% (Non Condence)
Storage Temperature
-20 °C ~ +70 °C
Protection Class
IP20
Cooling Type
Forced cooling with variable speed fan according to load %
Operation Altitude
? 1000 meter (from the sea level), at nominal load
Dimensions (mm), W x H x D
260x717x570 (with standard battery)
Weight W/O / W/Battery (kg) 38 / 93 (With Standart Battery)
Win Power Windows 95/98/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix4.3 and 5.1x, HP-UX 11.x, FreeBSD, Unix Systems, MAC Compatible Software Support
*Гаранция на устройството - 2 г.
Виж още UPS Artronic
Виж всички UPS в категорията
* High Reliability with the Digital Signal Processor (DSP) Control
* Power Extension and Redundancy with Parallel / Redundant Operation
* Parallel / Redundant connection up to 3 pcs
* High Reliability and Low Operation Cost
* Energy Efficiency with Input Power Factor Correction (PFC) Power Factor: 0,95-0,98
* Cooling System with Variable Speed Fans
* Automatic Restart and Cold Start Function
* Manual Bypass Switch
Technical Specifications
MODEL ART 1.1-10 kVA
Power(VA/Watt) 10000VA/7000W
Power(VA/Watt) - Paralelling With 3 pcs Parallel Connection, Total 30000 VA / 21000W
Voltage & Voltage Range 220 VAC, 1 Phase + Neutral
Voltage Tolerance 176 ? 276 VAC ± 3%
Power Factor ? 0.98
Current (nominal) 37 Ampere
Input Fuse 50 A NFB
Frequency & Frequency Range 50 Hz, 46 ~ 54 Hz
Working with Gen Set Perfect Voltage and frequency Compatibility
OUTPUT - INVERTER and BYPASS
Load Power Factor Range 0.65 inductive - 1.0 resistive
Voltage Wave Form Sinusoidal
Voltage & Voltage Tolerance 220 / 230 / 240 VAC ± 1%
Dynamic Response At 50% - 100 - 50% unbalanced load, max voltage decline < ± 5%
Recovery Time
At Dynamic load Changes, Output Voltage recovery time is 60 msec ± 1%
Total Harmonic Distortion For Linear Load ? 2%, Non Linear Load ? 6%
Frequency & Frequency Range 50 Hz / Mains 46-54 Hz, Battery Mode ± 0.1% (0.05 Hz)
Crest Factor 3 : 1
Over Load (Mains) For 105% - 130% load 10 mins., for > 130% load transfer to bypass after 1 sec, shutdown after 1 min at overloaded bypass
Over Load (Battery) At > 105% load shut down after 10 sec.
Short Circuit Protection Electronic short circuit protection, short circuit current 130% x Inom
Bypass and Transfer Time Standard static bypass, Completely Uninterrupted transfer between Mains - Battery / Battery - Mains
Bypass Voltage Tolerance 176 ? 261 VAC, 1 Phase + Neutral
BATTERY
Type and Placement Maintenance Free, Dry Type, Internal Maintenance Free, Dry Type, With External Battery Cabinet
Capacity and Number 12 V 9 Ah x 20 pcs
Battery Time (100% / 50% Load) 6 mins / 15 mins
Nominal Battery Voltage 240 VDC
Battery Low Voltage 220 VDC ± 3
Battery Charging Current and Charging Time
2 Ampere, 8 hours to 90% after complete discharge
INDICATORS & CONTROL PANEL
Type LED Panel
Control Panel Push Buttons (Open / Close, Audible Alarm Cancellation)
Measuring and Alarms % Load, Input Voltage Exist, Output Voltage Exist, Bypass Active, Battery Mode, Battery Capacity (%), Inverter in Service, Fault
Indicators (LED) Mains On, Mains Reverse, Battery Mode, Bypass On, Load / Battery Level, Overload, Fault
PROTECTIONS
Overload
Electronic Protection is available. In case of exceeding limits, the load is transferred to bypass without any interruption
Short Circuit
Inverter shuts down automatically
Over Temperature
If the internal Temperature is 90°C the load is transferred to bypass, When it returns < 80°C, Inverter starts to work
Modem / Network Protection
Modem / Network protection input against to Voltage Spikes
AUDIBLE ALARMS
Alarm Type and Alarms
Buzzer, it can be switched off by audible alarm button.
Battery Mode, Battery Low, UPS fault, Overload, Short Circuit, Over Charge, Charger, Bypass, Inverter fault, Communication fault
COMMUNICATION
Interface and Protocol
Standart DB 9 (Female) Port, Intelligent RS232 (standard), SNMP and AS400 Relay PCB (optional) DB25 parallel port (for paralelling)
Software
Free download from internet; communication and control from the network, Windows 95 / 98 / NT / 2000 / XP / 2003, Linux, Sun Solaris 7 / 8 / 9, IBM Aix4.3 ve 5.1x, HP-UX 11.x, FreeBSD, Unix Systems, MAC Compatible Software Support
GENERAL
Total Efficiency At 100% load 88%
Noise Level ? 55 dBA
Electro Magnetic Compatibility
EN 61000-4-2 (ESD), 4-3 (RS), 4-4 (EFT), 4-5 (surge), IEC 62040-2 (EMI)
Operation Temperature and Humidity
0 °C ~ 40 °C, maximum 20-90% (Non Condence)
Storage Temperature
-20 °C ~ +70 °C
Protection Class
IP20
Cooling Type
Forced cooling with variable speed fan according to load %
Operation Altitude
? 1000 meter (from the sea level), at nominal load
Dimensions (mm), W x H x D
260x717x570 (with standard battery)
Weight W/O / W/Battery (kg) 38 / 93 (With Standart Battery)
Win Power Windows 95/98/NT/2000/XP/2003, Linux, Sun Solaris 7/8/9, IBM Aix4.3 and 5.1x, HP-UX 11.x, FreeBSD, Unix Systems, MAC Compatible Software Support
*Гаранция на устройството - 2 г.
Виж още UPS Artronic
Виж всички UPS в категорията
Технически характеристики
Изходяща мощност: | 10000 VA |
---|---|
Формфактор: | Tower |
Добави Ревю / Въпрос
Оцени продукта или задай въпрос?
- 5
- 4
- 3
- 2
- 1
Свързани продукти
UPS PowerWalker DC SecureAdapter 10120431, 12VA/12W, малък UPS за устройства на 12V(рутери/декодери/IP камери), 2600 mAh Li-Ion батерия, до 3 часа поддръжка
61.14лв
UPS Hikvision DS-UPS600, 600VA/360W, Online, LCD дисплей, Tower
81.98лв
UPS Njoy Keen 600 UPLI-LI060KE-CG01B, 600VA/360W, Line Interactive, Tower
98.57лв