Ruijie RG-S2910-24GT4XS-UP-H(V3.0)
Network Security
With support for various types of ACLs, port security, IP-MAC-port binding, and other security technologies, the RG-S2910-H can effectively prevent various ARP spoofing and proactively protect against various DoS and DDoS attacks.
It supports Ruijie CPU Protection Policy (CPP) and Network Foundation Protection Policy (NFPP). The two technologies can be used to differentiate data flows destined for the CPU and assign priorities to queues for different processing. Moreover, the device delivers real-time bandwidth limiting to protect the CPU from being occupied by unauthorized traffic and malicious attacks, which guarantees stable CPU operation. It rate-limits ARP packets, ICMP request packets, and DHCP request packets sent by users on a network, and discards the packets of which the transmit rate exceeds the rate limit. It can also identify attacks and isolate users that launch attacks, ensuring secure and stable operation of the entire network.
VSU
Virtual Switching Unit (VSU) enables multiple physical devices to be virtualized into one logical device. The physical devices use the same IP address, Telnet process, and CLI for management, and support automatic version check and automatic configuration. In this context, a network administrator only manages one logical device, improving working efficiency and experience.
Simplified management: The network administrator can manage multiple switches uniformly without connecting to each switch for separate configuration and management.
Simplified network topology: A VSU serves as a switch on a network and connects to peripheral devices through aggregate links. Therefore, no Layer 2 loop occurs and MSTP configuration is not required. Various control protocols can run on the VSU.
Fault rectification within milliseconds: A VSU connects to peripheral devices through aggregate links. If one device or member link in the VSU malfunctions, data and services can be switched to another member link within only 50 ms to 200 ms.
High scalability: Devices can be added to or removed from a virtualized network, without affecting normal operation of other devices.
Increase in return on investment: Aggregate links are used for connecting the VSU to peripheral devices, implementing link redundancy and load balancing. All network devices and bandwidth resources are fully leveraged. Any type of 10GE ports can be used to establish a VSU over any data transmission cable, without requiring additional cable or expansion card configurations. There are no limitations on the port or cable types used, which maximizes user investment protection.
Standard Protocols for Easier Device Interworking
The RG-S2915-L series switches support the Ethernet Ring Protection Switching (ERPS) technology, which is a Layer 2 link redundancy protocol designed for the core Ethernet. The master device is used to block loops and restore links, and the non-master device directly reports the link status to the master device, without any processing from other non-master devices. Therefore, loop elimination and restoration time of ERPS is faster than that of STP. ERPS supports link restoration within milliseconds.
SDN for Future Service Development
The RG-S2910-H supports OpenFlow, and can be used with Ruijie Networks' Software-defined Networking (SDN) controller to easily realize large-scale 2-layer networking architecture. It also supports smooth upgrade of the entire network to an SDN network, which greatly simplifies network management while reducing maintenance costs.
Hardware Specifications
Hardware Specifications | RG-S2910-24GT4XS-UP-H |
Ports | |
Fixed service port | 24 x 10/100/1000M electrical ports supporting auto negotiation + 4 x 10GE/1GE SFP+ ports |
System | |
Switching capacity | 128 Gbps |
Packet forwarding rate | 96 Mpps |
Dimensions and Weight | |
Dimensions (W x D x H) | 440 mm x 260 mm x 44 mm (17.32 in. x 10.24 in. x 1.73 in.) |
Power Supply and Consumption | |
Rated input voltage | AC input: rated voltage range 100 V to 240 V, frequency 50/60 Hz |
Maximum input voltage | AC input: rated voltage range 90 V to 264 V, frequency 50/60 Hz |
Input voltage | High voltage DC (HVDC) input: input voltage range 192 V to 290 V |
PoE power supply | 24 x electrical ports supporting PoE and PoE+ |
Maximum output power of a PoE interface | Maximum PoE/PoE+ output power: 370 W |
Environment and Reliability | |
Fan monitoring | Fan speed adjustment and fault alarms |
Operating temperature | 0°C to 50°C (32°F to 122°F) |
Storage temperature | –40°C to +70°C (–40°F to +158°F) |
Operating humidity | 10% to 90% RH |
Storage humidity | 5% to 95% RH |
Operating altitude | –500 m to +5000 m (–1640.42 ft to +16404.20 ft) |
Software Specifications
Software Specifications | RG-S2910-24GT4XS-UP-H |
VLAN | 4K VLANs Interface-based VLAN assignment MAC address-based VLAN assignment Protocol-based VLAN assignment Private VLAN Voice VLAN IP subnet-based VLAN GVRP |
QinQ | Basic QinQ Selective QinQ |
ACL | Standard IP ACL Extended IP ACL Extended MAC ACL (hardware ACL based on the source MAC address, destination MAC address, and optional Ethernet type) Time range-based ACL Expert-level ACL (hardware ACL based on flexible combinations of the VLAN ID, Ethernet type, MAC address, IP address, TCP/UDP port ID, protocol type, and time range) ACL 80 IPv6 ACL Global ACL ACL redirection |
QoS | Rate limiting on an interface based on the ingress or egress Flow-based rate limiting on the ingress or egress 802.1p/DSCP/ToS traffic classification Eight priority queues per interface SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR, and RED/WRED scheduling |
Mirroring | Common service interfaces and aggregate interfaces that can be configured as source and destination interfaces of mirroring 1:1, 1:N, N:1, and flow-based local and remote mirroring RSPAN and ERSPAN Cross-device traffic mirroring |
DHCP | DHCP server DHCP client DHCP snooping DHCP relay IPv6 DHCP snooping IPv6 DHCP client IPv6 DHCP relay |
Layer 2 protocols | IEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.3x, IEEE 802.3ad, IEEE 802.1p, IEEE 802.1x, IEEE 802.3ab, IEEE 802.1Q (GVRP), IEEE 802.1d, IEEE 802.1w, IEEE 802.1s IEEE 802.1s, and IGMP snooping v1/v2 |
Security | 3-tuple binding (IP address, MAC address, and interface) 3-tuple binding (IPv6 address, MAC address, and interface) Invalid MAC address filtering Interface- and MAC address-based 802.1X authentication MAC address bypass authentication (MAB) Portal and Portal 2.0 authentication ARP check DAI Trusted ARP ARP spoofing prevention Broadcast or multicast storm suppression Unknown multicast suppression and multicast bandwidth suppression Hierarchical management and password protection RADIUS and TACAS+ AAA (IPv4/IPv6) for device login management SSH and SSHv2.0 BPDU guard IP source guard CPP and NFPP Port protection |
Cable diagnostics | Cable detection |
Energy Efficient Ethernet (EEE) | IEEE 802.3az-compliant EEE: When EEE is enabled, power consumption of interfaces is significantly reduced. |
Port sleeping | Port sleeping |
PoE | IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt Automatic and energy-efficient power supply management modes Warm start to implement uninterrupted power supply Interface priority Compatibility with non-standard PDs Scheduled power-on/off of PoE interfaces |
IP routing | IPv4/ IPv6 static route RIP, RIPng, OSPFv2, and OSPFv3 Routing policy |
IPv6 Basic protocols | IPv6 addressing, Neighbor Discovery (ND), IPv6 ACL, ICMPv6, IPv6 ping, and IPv6 tracert |
VSU features | VSU Local and remote stacking Cross-chassis link bundling within the stack |
Zero Touch Provisioning (ZTP) | CWMP (TR-069) standard protocol |
Management features | SNMP, CLI (Telnet/console), RMON, SSH, Syslog/debugging, NTP/SNTP, FTP, TFTP, web, and sFlow |
Виж още Суич Ruijie
Виж всички продукти Суич в категорията
Брой портове: | 28 |
---|---|
Максимална скорост: | 1 Gbit/s |
Стандарт: | 802.3bt |
Управляем: | Не е указано |
- 5
- 4
- 3
- 2
- 1
-
Суич Ubiquiti UniFi Switch Pro Max 24 PoE, 26 порта, 8 10/100/1000Mbps RJ45 PoE+, 8x 10/100/1000Mbps RJ45 PoE++, 8x 100/1000/2500Mbps RJ45 PoE++, 2x 10G SFP+
1799.88лв
-
Суич ZyXEL XGS1930-52, 10000 Mbps, 48x 10/100/1000Base-T, 4x 10GE SFP+ with Uplink, 512MB RAM, 32MB Flash
1795.57лв
-
Суич Ubiquiti USW-Enterprise-24-PoE, 1000Mbps, 26 порта, 1000Mbps, 26x 10/100/1000 Base-T PoE, 2x SFP+ 10 Gbps
1812.97лв